SUA750RMI2U - APC Smart-UPS 750VA APC-RMI Line Interactive Rackmount 2U - UPSO1-3 (NOT AVAILABLE IN THE UK)
Description:
APC Smart-UPS 750VA USB RM 2U 230V APC Smart-UPS, 480 Watts / 750 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB, Rack Height 2 U Includes: CD with software, Rack Mounting brackets, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable, User Manual
Features:
SUA750RMI2U Features
USB connectivity - Provides management of the UPS via a USB port (not available on all models).
Front-access servicing - Simplifies installation and maintenance while minimizing space requirements.
Specification:
Output
Output Power Capacity- 480 Watts / 750 VA
Max Configurable Power- 480 Watts / 750 VA
Nominal Output Voltage - 230V
Output Voltage Note- Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion- Less than 5% at full load
Output Frequency (sync to mains)- 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Crest Factor - up to 5 : 1
Waveform Type- Sine wave
Output Connections - (4) IEC 320 C13 and (2) IEC Jumpers
Input
Nominal Input Voltage -230V
Input Frequency - 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections - IEC-320 C14
Input voltage range for main operations - 160 - 286V
Input voltage adjustable range for mains operation - 151 - 302V
Battery Type-
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time - 3 hour(s)
Replacement Battery - RBC22
RBC™ Quantity - 1
Typical Backup Time at Half Load - 16.6 minutes (240 Watts)
Typical Backup Time at Full Load - 5.5 minutes (480 Watts)
Communications & Management
Interface Port(s) - DB-9 RS-232,SmartSlot,USB
Available SmartSlot™ Interface Quantity - 1
Control panel - LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : and Overload Indicators
Audible Alarm - Alarm when on battery : distinctive low battery alarm : configurable delays
Emergency Power Off (EPO) - Optional
Surge Protection and Filtering
Surge energy rating - 480 Joules
Filtering - Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Physical
Maximum Height - 89.00 mm
Maximum Width - 432.00 mm
Maximum Depth - 457.00 mm
Rack Height - 2U
Net Weight - 21.82 KG
Shipping Weight - 25.11 KG
Shipping Height - 254.00 mm
Shipping Width - 594.00 mm
Shipping Depth - 603.00 mm
Color – Black
Environmental
Operating Environment - 0 - 40 °C
Operating Relative Humidity - 0%
Operating Elevation - 0-3000 meters
Storage Temperature - -15 - 45 °C
Storage Relative Humidity - 0%
Storage Elevation - 0-15000 meters
Audible noise at 1 meter from surface of unit - 36.00 dBA
Online Thermal Dissipation - 68.00 BTU/hr
Conformance
Regulatory Approvals - C-tick,CE,EN 50091-1,EN 50091-2,TUV,VDE
Standard Warranty - 2 years repair or replace
Environmental Compliance - RoHS 7b Exemption