BCM2-DIN-KIT-Y01 BCM2: BRANCH CIRCUIT METERS & CONTROLLER Power Panel Distribution Board Meter: Input: 3 Phase 250A, Output: 24x Single Phase Branch Circuits INCLUDING Controller
Description:
BCM2: BRANCH CIRCUIT METERS & CONTROLLER This next generation BCM leverages the same metering and controller technology in Raritan’s 3rd generation rack PDUs to track power upstream from IT equipment racks. It measures KWh with ISO/SEC +/- 0.5% billing-grade accuracy for accurate customer chargeback reports and energy efficiency initiatives.
Features:
Auto Correcting CTs For Fast Installation -
Raritan's new BCM system was redesigned with help from leading customers and installers in real-world settings. Auto-correcting split core CTs snap around live circuits - in either direction - without power to equipment racks being cut off.
Cost Effective, Modular & Scalable System -
The new easy-to-install modular system is available as either a branch circuit monitor or busway monitor kit. Because it is modular, it can be scaled as and when needed, making it more cost effective than competitive solutions
Most Accurate Metering in the Market -
The BCM leverages the same metering and controller technology in Raritan’s 3rd generation rack PDU’S to track power upstream from IT equipment racks. It measures KWh with ISO/SEC +/- 0.5% billing-grade accuracy for accurate customer chargeback reports and energy efficiency initiatives.
Real-Time Configurator for Quick Setup -
The BCM system can easily be configured by uploading the panel schedule via USB stick, thereby eliminating manual input errors. Fully compatible and it integrates with Sunbird Power IQ DCIM Monitoring software that helps to consolidate facility power and environmental data.
- Meters Floor PDU, RPPs, Panelboards,
and Busways
- One controller supports up to
70 power meters
- Quick configuration via USB stick
preloaded with panel schedule
- CTs connect to live circuits
- Auto-correct metering adjusts for CT
orientation on wires
- Real-time configurator
- USB ports for configuration, Wi-Fi
networking, and tablet display
- Supported by DCIM software that
offers auto-discovery as a panel
- Several enclosure options
- Same firmware as Raritan rack PDUs
- Remote display using PDView app
- Collects data on: A, V, kW, kVA, power
factor, and kWh
- Protocols include TCP/IP,
Modbus and SNMP
- Environmental sensor support
Raritan BCM2 How it works full
Specification:
Power Panel Distribution Board Meter: Input: 3 Phase 250A, Output: 24x Single Phase Branch Circuits INCLUDING Controller
1x PMC-1001 (Rack/Wall Mount Power Meter Controller)
1x PMM-1000 (3PH, 480V AC DIN Rail Power Meter Module)
1x PMB-1960 (96 Port Power Meter Branch)
1x BCM2-250A-CT-4PK (4x 250A Current Transformers/~0.5% Accuracy/333mV/24"/610mm Lead)
1x BCM2-MCTcable-3M (Mains Circuit Cable for 5x CTs)
2x BCM2-60A-CT-12PK (12x 60A Current Transformers/~0.5% Accuracy/333mV/24"/610mm Lead)
1x BCM2-BCTcable-3M-1
1x BCM2-BCTcable-3M-2
1x BCM2-BCTcable-3M-3
1x BCM2-BCTcable-3M-4