PX3-1170U - Raritan Unit Metered iPDU: 3 Phase, 208V, 3-Phase Wye (L-N), 5.8kVA, 16A 16A, 27 Outlets: 21x IEC C13, 6x IEC C19, Plug Type: IEC 60309 32A, 7.36 kVA, Ethernet, Serial, USB-A, USB-B, Sensor Connections (PX-1000 Series) BTO

Raritan PX3-1170U

Description:

Rack Power Distribution Units for Your Data Center Raritan’s PX3-1000 intelligent rack PDU series offers more than just power distribution -- it’s a launch pad for real-time remote BAR level power monitoring, environmental sensors, data center infrastructure management, and so much more. The PX series offers hundreds of models to power all your data center applications, including high density applications, and 400V three-phase power distribution. Raritan offers a variety of intelligent rack power distribution models that satisfy all of your metering requirements. Get certain off-the-shelf models delivered in as little as a few days, or have your PDUs engineered to meet your unique application. In the next few pages you’ll learn how Raritan was able to take over twenty-five years of embedded computing expertise and customer insights to reinvent the rack PDU and set the gold standard for data center power chain management. Find out why some of the world’s largest data centers trust Raritan’s intelligent rack PDUs to power their mission critical equipment. kWH Metering Accuracy Accurate kWh metering allows you to measure actual energy usage for accurate customer or department charge-back billing. The data can be used to encourage energy efficient behavior among users, establish power consumption baselines, and analyze the effect of efficiency initiatives. Soaring energy prices, greater competition in the marketplace, and global concerns over climate change are forcing companies to reconsider how they utilize power in the most valuable and energy intensive resource they own – the data center. It’s why data centers are now so focused on cutting operational costs by improving efficiencies, and making optimal use of energy, space, and cooling. They’re also tasked with the most important responsibility of all: to make sure the data, services, and pplications that we all rely on are always available. Not surprisingly, many of the major strategies being employed to address these challenges depend on capabilities that were not present in the simple commodity power strips of a few years ago. Consider how Raritan’s intelligent rack power distribution units (iPDUs) help data centers to achieve those goals.

Features:

Energy Metering

Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor

Metering Accuracy

ISO/IEC 62053-21 1%

Remote Outlet Switching

No

Metering per input line

Yes

Metering per Branch Circuit Breaker

No

Environmental Sensor Ready

Yes

Compatible Sensors

Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.

View all sensors.

Cascading

Yes, Max 16 PDUs can be daisy chained using a USB or Ethernet connection.

Networking

Primary (10/100/1000 Base T) Ethernet with secondary redundant (10/100/1000 Base T) Ethernet in 0U, (10/100 Base T) Ethernet in 1U/2U/3U. Optional Wi-Fi (802.11ac/a/b/g/n).

Onboard Display

Color, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation



Specification:

PX3-1170U - Raritan Unit Metered iPDU: 3 Phase, 208V, 3-Phase Wye (L-N), 5.8kVA, 16A 16A, 27 Outlets: 21x IEC C13, 6x IEC C19, Plug Type: IEC 60309 32A, 7.36 kVA, Ethernet, Serial, USB-A, USB-B, Sensor Connections (PX-1000 Series) BTO

BTO - (BUILT TO ORDER)

Input
Input Plug

NEMA L21-20P

Nominal Voltage

208V

Maximum Input Current

20A

Rated Input Current

16A

Power Capacity

5.8kVA

Cord Length

3m

Output
Nominal Voltage

240V

Receptacles (Output Connections)

(21) C13, (6) C19, (3) NEMA 520R

Overload Protection

N/A

Physical
Dimensions (WxDxH)

TBD

Unit Weight

13kg

Shipping Weight

16.975574kg

Shipping Dimensions

1819 x 230 x 118 mm

Mounting

Tool-less Button Mount

Environmental
Operating Temperature/Environment

60 C

Operating Relative Humidity

85%

Operating Elevation

0-6000ft

Conformance
Regulatory Approvals

UL

Warranty

Standard 2 years manufacturer warranty

Tender Text/Bid Submittal Text
Monitored rack power distribution unit (0U [vertical], 5.8kVA, 30 outlets). INPUT: 208v (3-phase WYE), 20a - NEMA L21-20P plug (4P5W); OUTPUT: 21@ C13, 12@ C19 outlets; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Max Dimensions 52mm x 55mm x 1780mm (2.1in x 2.2in x 70.1in). Max Weight TBD. Maximum ambient temperature 60C at full load.

Vendor: Raritan; Part Number: PX3-1170U