PX3-1923X2 Raritan PX3 2xAB 230v 32A 42x outlets(36) C13, (6) C19 PDU Bar Monitoring

PX3-1923X2 Raritan PDU

Description:

Raritan 2 x Input PDU 32A Single phase to module 1&2 plus a 32A 32A Single phase to module 3&4 Outlets sets. Each outlet set ( 6xC13 & 2xC19) The Raritan PX-1000 family of high-quality rack power distribution units (PDUs) offers real-time remote unit-level power monitoring of current (amps), voltage, power (kVA, kW), power factor and energy consumption (kWh) with ISO/IEC +/- 1% billing-grade accuracy. The PX-1000 also supports Raritan’s plug-and- lay environmental sensors. Users can define thresholds and receive alerts when thresholds are crossed for both power and environmental events.

Features:

Raritan 2 x Input PDU
32A Single phase to module 1&2 plus a 32A 32A Single phase to module 3&4 Outlets sets.
Each outlet set ( 6xC13 & 2xC19)

Energy Metering: Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor

Metering Accuracy: ISO/IEC 62053-21 1%

Remote Outlet Switching:No

Metering per input line:Yes

Metering per Branch Circuit Breaker:No

Environmental Sensor Ready:Yes

Compatible Sensors:Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure.

See compatible parts-

PDU Linking:Link up to 8 PDUs where the Primary PDU has knowledge and power information from the attached Expansion PDUs. Redundant power from the first expansion unit ensures uptime even if the Primary PDU loses power.

Cascading:Physically cascade 32 PDUs under one ethernet port or 16 PDUs with USB using bridging mode, or additionally, save IP addresses using a single IP address with port forwarding.

Networking:(10/100/1000 Base T) Ethernet, Secondary redundant (10/100/1000 Base T) Ethernet. Optional WiFi (802.11 a/b/g/n).

Onboard Display:Colour, matrix LCD display : Voltage, current, or active power (per line, per breaker, or per receptacle / outlet); Alarms; Configuration information (name, ratings, IP / Networking information). Auto-flip orientation

Dual power input 309's feeding different banks on the PDU.


Specification:

Input
Input Plug X2 32A TO Separate bank sets. Terminals_AC
Nominal Voltage:230V
Maximum Input Current:nullA
Rated Input Current:nullA
Power Capacity:nullkVA
Cord Length: 3m x2


Output
Nominal Voltage:240V
Receptacles (Output Connections) :(36) C13, (6) C19
Overload Protection:N/A
Physical


Dimensions Body (WxDxH) 52x55x1856
Unit Weight: 18 lbs
Shipping Weight: 24.691744 lbs
Shipping Dimensions: 1986 x 230 x 118 mm
Mounting: RACK-KIT-PX2-1K-ZU

Environmental
Operating Temperature/Environment: 60 C

Operating Relative Humidity: 85%

Operating Elevation:0-6000ft

Conformance
Regulatory Approvals:CE

Warranty:Standard 2 years manufacturer warranty


Tender Text/Bid Submittal Text
Monitored rack power distribution unit (0U [vertical], 14.7kVA, 42 outlets). INPUT: 230v, 32a - IEC 60309 2P+E 6h 32A plug (2P3W); OUTPUT: 36@ C13, 6@ C19 outlets; on 4@ 1-pole, 16a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Breaker metering and alarming (0V detection). Max Dimensions 52mm x 55mm x 1856mm (2.1in x 2.2in x 73.1in). Max Weight 8.3 kg. Maximum ambient temperature 60C at full load.

Vendor: Raritan; Part Number: PX3-1923X2