EMCU-1-1C ServerTech Environmental Monitor Control Unit with (1) combination Temperature & Humidity Probe 10ft (3m)



Description:

IP-based Solution for Monitoring Environmental Conditions in the Data Center Equipment Cabinet Ever increasing densities of vertically racked servers conserve valuable floor space in the data center, but the resulting power consumption and heat dissipation create new concerns for data center managers. Environmental Monitoring, particularly temperature & humidity, is a must for any sensitive infrastructure. The most recent ASHRAE thermal guidelines suggests three measurement points in the equipment rack. Server Technology Smart and Switched PDUs support two combination temperature/humidity probes on the Master unit. Newer Expansion units support two additional sensors. If additional probes are required, the EMCU-1-1C Environmental Monitor provides additional inputs.

Features:

The EMCU-1-1C assures network managers that environmental conditions are within defined tolerances and that unauthorized entry into the equipment cabinets does not go unnoticed.


The EMCU-1-1C can be located in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, and any unmanned area that needs to be monitored Install the EMCU-1-1C in the equipment cabinet and gain access to environmental conditions from a web or serial interface through one of Server Technology’s address-able PDUs.

Each EMCU supports:
• 2 additional temperature and humidity measurements (EMTH-2-10)
• Water sensor (EMWS-1-1)
• 4 dry contact closure door sensors



Specification:

PARTS AND CONPATIBLE PARTS INFORMATION.

THIS PART IS ONLY SUPPLIED WITH 1x Temperature & Humidity Probe 10ft (3m)



Analog Sensor Accepts 3rd party analog sensors. Input 0 V to +5 VDC
Water Sensor Probe 1 ft (0.3 m) water sensing cable, 10 ft (3 m) connector cord, flexible thermally bonded
polymer coated sensor for increased strength and durability
Contact Closure Sensors Accepts up to four 3rd party contact closer sensors. Wago® spring-loaded 3-position
terminal block
LED Confirmation Indicators Signal “Fault” conditions to contact closures
Web Interface Temperature, Humidity, Water Detection, Door Cabinet Status
Measurement Range 0% to 100% RH / 0 °C to 100 °C
Temperature Accuracy 0 °C to 100 °C: < +/- 1 °C
Absolute RH Accuracy 0% to 100% RH: <+/- 3.5%
Dimensions (H x W x D) EMCU-1-1C: 4.57 x 2.32 x 1.22 in. (116 x 59 x 31 mm)
Weight EMCU-1-1C: 8.8 oz. (250 g), EMTH-2-10: 2.1 oz. (60 g), EMWS-1-1: 3.2 ox. (91 g)


COMPATIBLE SENSORS:

SVT-EMTH-1-10 3 Mtr
SVT-EMTH-1-20 6 Mtr
SVT-EMWS-1-1

4 x DRY CONTACTS Door closure sensors






compatible products

POA - please ...order by telephone/email/fax

Qty: